Enphase, M215-IG Microinverter, 215W, 240/208VAC, 60Hz, 16-45VDC for 60 cell modules, MC Locking Connector in, 16" Engage Cable out, with integrated ground, 25 Yr Warr, M215-60-2LL-S22-IG


The Enphase M215-IG Microinverter (M215-60-2LL-S22-IG) with integrated ground delivers increased energy harvest and reduces design and installation complexity with its all-AC approach. With the advanced M215, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This further simplifies installation, enhances safety, and saves on labor and materials costs.The Enphase M215 integrates seamlessly with the Engage Cable, the Envoy Communications GatewayTM, and Enlighten, Enphase’s monitoring and analysis software.

Features
  • Powerful & Versitile - Maximizes energy production. No GEC needed for microinverter. No DC design or string calculation required.
  • Efficient - Minimizes impact of shading, dust, and debris. Easy installation with Engage Cable.
  • Safe & Reliable -No single point of system failure. More than 1 million hours of testing and millions of units shipped. Industry-leading warranty, up to 25 years.
csa.jpg  
Electrical Data
 
Recommended Input Power (STC): 190-270 Watts
Maximum Input DC Voltage: 48 Volts
Peak Power Tracking Voltage: 27-39 Volts
Operating Range: 16-48 Volts
Min/Max Start Voltage: 22 V / 48 Volts
Max DC Short Circuit Current: 15 Amps
Max Input Current: 10 Amps
Peak Output Power: 225W @208 VAC, 225W @240 VAC
Rated (Continuous) Output Power: 215W @208 VAC, 225W @240 VAC
Nominal Output Current: 1.1A @208 VAC, 0.9A @240 VAC
Nominal Voltage/Range: 208V / 183-229V @208 VAC, 240V / 211-264V @240 VAC
Nominal Frequency/Range: 60.0 / 27-61 Hz @208 VAC, 60.0 / 57-61 Hz @240 VAC
Power Factor: >0.95 @208 VAC, >0.95 @240 VAC
Max Units per 20A Branch Circuit: 25(Three Phase) @208 VAC, 17 (Single Phase) @240VAC
Max Output Fault Current: 850 mA rms for 6 cycles @208 VAC, 850 mA rms for 6 cycles @240 VAC
CEC Weighted Efficiency: 96.5% @208 VAC, 96.5% @240 VAC
Peak Inverter Efficiency: 96.5%
Static MPPT Efficiency: 99.4%
Night Time Power Consumption: 65 mW Max
Mechanical Data
 
Technology: Micro-Inverter
Dimensions:
6.73 x 6.81 x 1.18 Inches
Weight: 3.40 lbs
Enclosure Environmental Rating: Outdoor - NEMA6
Cooling: Natural Convection - No Fans
Compatibility: Compatible with 60-Cell PV Modules
Communication: Power Line
Integrated Ground: The DC circuit meets the requirements for ungrounded PV arrays inNEC 690.35. Equipment ground is provided in the Engage Cable. No additional GEC or ground is required. Ground fault protection (GFP) is integrated into the microinverter.
Monitoring: Enlighten Manager and MyEnlighten Monitoring Options
Compliance: UL1741/IEEE1547, FCC Part 15 Class B, CAN/CSA-C22.2 NO. 0-M91, 0.4-04, and 107.1-01
Ambient Temperature Range: -40 to +65°C