Enphase, M215-IG Microinverter, 215W, 240/208VAC, 60Hz, 16-45VDC for 60 cell modules, MC Locking Connector in, 16" Engage Cable out, with integrated ground, 25 Yr Warr, M215-60-2LL-S22-IG
The Enphase M215-IG Microinverter (M215-60-2LL-S22-IG) with integrated ground delivers increased energy harvest and reduces design and installation complexity with its all-AC approach. With the advanced M215, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This further simplifies installation, enhances safety, and saves on labor and materials costs.The Enphase M215 integrates seamlessly with the Engage Cable, the Envoy Communications GatewayTM, and Enlighten, Enphase’s monitoring and analysis software.
|
Features
-
Powerful & Versitile - Maximizes energy production. No GEC needed for microinverter. No DC design or string calculation required.
-
Efficient - Minimizes impact of shading, dust, and debris. Easy installation with Engage Cable.
-
Safe & Reliable -No single point of system failure. More than 1 million hours of testing and millions of units shipped. Industry-leading warranty, up to 25 years.
Electrical Data
|
|
Recommended Input Power (STC): |
190-270 Watts
|
Maximum Input DC Voltage: |
48 Volts
|
Peak Power Tracking Voltage: |
27-39 Volts
|
Operating Range: |
16-48 Volts
|
Min/Max Start Voltage: |
22 V / 48 Volts
|
Max DC Short Circuit Current: |
15 Amps |
Max Input Current: |
10 Amps |
Peak Output Power: |
225W @208 VAC, 225W @240 VAC |
Rated (Continuous) Output Power: |
215W @208 VAC, 225W @240 VAC |
Nominal Output Current: |
1.1A @208 VAC, 0.9A @240 VAC |
Nominal Voltage/Range: |
208V / 183-229V @208 VAC, 240V / 211-264V @240 VAC |
Nominal Frequency/Range: |
60.0 / 27-61 Hz @208 VAC, 60.0 / 57-61 Hz @240 VAC |
Power Factor: |
>0.95 @208 VAC, >0.95 @240 VAC |
Max Units per 20A Branch Circuit: |
25(Three Phase) @208 VAC, 17 (Single Phase) @240VAC |
Max Output Fault Current: |
850 mA rms for 6 cycles @208 VAC, 850 mA rms for 6 cycles @240 VAC |
CEC Weighted Efficiency: |
96.5% @208 VAC, 96.5% @240 VAC |
Peak Inverter Efficiency: |
96.5% |
Static MPPT Efficiency: |
99.4% |
Night Time Power Consumption: |
65 mW Max |
Mechanical Data
|
|
Technology: |
Micro-Inverter |
Dimensions:
|
6.73 x 6.81 x 1.18 Inches |
Weight: |
3.40 lbs |
Enclosure Environmental Rating: |
Outdoor - NEMA6 |
Cooling: |
Natural Convection - No Fans |
Compatibility: |
Compatible with 60-Cell PV Modules |
Communication: |
Power Line |
Integrated Ground: |
The DC circuit meets the requirements for ungrounded PV arrays inNEC 690.35. Equipment ground is provided in the Engage Cable. No additional GEC or ground is required. Ground fault protection (GFP) is integrated into the microinverter. |
Monitoring: |
Enlighten Manager and MyEnlighten Monitoring Options |
Compliance: |
UL1741/IEEE1547, FCC Part 15 Class B, CAN/CSA-C22.2 NO. 0-M91, 0.4-04, and 107.1-01 |
Ambient Temperature Range: |
-40 to +65°C |
|